UPS Kenika MS-20KVA ini adalah UPS online. UPS online merupakan UPS yang paling lengkap proteksinya. UPS online menghasilkan tegangan output yang sangat stabil, tidak ada transfer time pada saat perpindahan dari listrik utama/PLN ke baterai, dan mempunyai gelombang sinus, sama seperti gelombang listrik yang dihasilkan oleh PLN.
Karena menghasilkan gelombang SINUS seperti gelombang yang dihasilkan listrik PLN maka UPS Kenika MS-20KVA ini sangat direkomendasikan untuk beban yang kritis seperti: peralatan laboratorium, peralatan kedokteran, server komputer atau beban kritis lainnya.
1. Authentic realize the high frequency online double conversion;
2. The high performance machine using DSP technology;
3. The output power factor can reach 0.8;
4. The battery quantity can be adjusted during 16-20 piece;
5. Charging current can be adjusted from 0.5-6A through the LCD and software;
6. Single phase with widely AC input range: 110-300VAC;
7. Emergency Power Off (EPO);
8. ECO mode provide energy-saving effect;
9. Three phase input including the power factor correction function;
10. Three-stage extensible charging design, to make sure the battery with more superior performance;
11. N + X parallel redundancy in application;
12. Widely used in financial, telcom, government, traffic, manufacture, education etc.
Specifications:
MODEL | MS-20KVA | |
Specification | 3 Phase INPUT & 3 Phase OUTPUT | |
Capacity | 20KVA / 16KW | |
INPUT | ||
Input Voltage | 3 × 400 VAC (3 Ph + N) | |
Voltage Range | 190 – 520 VAC (3-Phase) at 50% Load; 305 – 478 VAC (3 Phase) at 100% Load | |
Frequency Range | 46 – 54Hz or 56 – 64Hz | |
Power Factor | ≥ 0.99 @ 100% Load | |
OUTPUT | ||
Output Voltage | Three Phase 380VAC (3 Ph + N) | |
Voltage Range (Battery Mode) | ± 1% | |
Frequency Range(Synchronous Correction Range) | 46 – 54Hz or 56 – 64Hz | |
Frequency Range (Battery Mode) | 50Hz ± 0.1Hz or 60Hz ± 0.1Hz | |
Surge Ratio | 3 : 1 (Max) | |
THD | ≤ 2% THD (Linear Load), ≤ 5% THD (Unlinear Load) | |
Transfer Time | 0ms | |
Wave Form (Battery Mode) | Pure Sine Wave | |
Protection | Over Charging, Over Discharge, Short Circuit, Overload, Power Surge | |
Overload | 150% for 1 Minute, 125% for 2 Minutes | |
EFFICIENCY | ||
AC Mode | 89% | |
Battery Mode | 88% | |
BATTERY | ||
Long Running Machine | Quantity | 20 Piece (Optional During 16 – 20 Piece) |
Max. Charging Current | 4A | |
Charging Voltage | 273VDC ± 1% | |
DISPLAY INSTRUCTION | ||
LCD or LED | Load Power, Battery Capacity, AC Model, Battery Model, Bypass Mode, Fault Indication | |
WARNING VOICE | ||
Battery Mode | Sounding Every 4 Second | |
Battery with Low Power | Sounding Every 1 Second | |
Overload | Sounding Every 0.5 Second | |
Mistake | Continuously Sounding | |
PHYSICAL PROPERTIES | ||
Long Running | Size | 592 mm × 250 mm × 826 mm |
Nett Weight | 50 kg | |
ENVIRONMENT | ||
Humidity | 0 – 95% RH @ 0-40°C (No Frost) | |
Noise | < 65dB @ 1 meter | |
CONTROL MANAGEMENT | ||
RS-232 / USB | Support Windows 2000/2003/XP/Vista/2008/7/8, Linux, Unix, and MAC | |
Optional SNMP | Power Management Support SNMP Management and Network Management | |
Standard Package | Wooden Case |